User Manual
Transcripción
User Manual
The Intelligent Surveillance Solution SCB-C24 User Manual Ver. 1.0.120723.00 The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System TABLE OF CONTENTS TABLE OF CONTENTS ............................................................................................................................. 1 1. INTRODUCTION .................................................................................................................................. 2 1.1.Key Features ......................................................................................................................................................... 3 1.2. OS Requirement .................................................................................................................................................. 4 1.3. Hardware Requirement..................................................................................................................................... 4 1.4. Specification ........................................................................................................................................................ 5 2. OVERVIEW .......................................................................................................................................... 7 2.1. Pin Definition ........................................................................................................................................................ 8 3. CONFIGURE PROTOCOL & SELF-TEST ............................................................................................ 9 3.1. Communication Defaults ................................................................................................................................ 10 3.2. Back to Initial ..................................................................................................................................................... 11 4. NETWORK DEPLOYMENT DIAGRAM ............................................................................................ 12 5. HARDWARE SETUP ........................................................................................................................... 13 5.1. Connect C08 to Server PC.............................................................................................................................. 13 5.2. Connect C24 to C08 ........................................................................................................................................ 14 5.3. Connect C24 to Power Supply ...................................................................................................................... 14 5.4. Connect Peripherals to C24 & Power Supply.............................................................................................. 14 5.5. Check C24 COM port, Baud Rate & Address ............................................................................................. 14 5.6. Configure Mainconsole ................................................................................................................................... 15 -1- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 1.Introduction C24 is an I/O box to intermediate the communication between a surveillance server and multiple peripherals. It joins up all the major components in your surveillance network to deliver your prospective management and protection over your property. This manual combs the hardware/software setup for C24. Hardware-wise C24 needs a converter (C08), and software-wise the server relies on a piece of surveillance recording software, Mainconsole, to bring all the peripherals under control. Easy-to-mount and flexible in communication, C24 will be the pivot in your surveillance network. Thank you for choosing C24. -2- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 1.1.Key Features - Supports wide range of DC-in voltages. Supports ASCII and Modbus/RTU protocols Supports baud rates from 1.2Kbps to 115.2 Kbps. Digital output signal with 3750Vrms isolation protection Supports dual watchdog: Hardware (module) watchdog & software (host) watchdog. External dip-switch to deliver configuration and hardware self-test. Status LED for each channels DIN-Rail and panel mount support. Support screw terminal Includes external DC power adaptor. -3- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 1.2. OS Requirement 32 bits MS Windows XP pro SP3 / Vista SP1 / Win 7 SP1 64 bits Win 7 SP1/ Win Server 2008 R2 1.3. Hardware Requirement D C B A 2200~1400 1400~1050 1050~550 550~ CPU Intel Core I7 Intel Core I5 Intel Core 2 Quad Q9400 Intel Core 2 Duo E5300 RAM 2 GB 2 GB 2 GB 1 GB Motherboard Intel 55 or 57 chip or above, MB vendor Asus, Gigabyte or Intel with Intel Chipset recommended * S of all cam Display card Intel 35 or 33 chip or above, MB vendor Asus, Gigabyte or Intel with Intel Chipset recommended ATI Radeon HD 4350 or above (ATI Driver V11-5 recommended ATI Driver V10 not support) Ethernet 100 baseT or above, Gigabit LAN recommended Hard Disk 250 GB or above OS Windows XP (32-bit) / Windows 7 (32 and 64-bit) / Windows 2008 (64-bit) *S=M x N N: FPS of Camera M:Value of IP camera resolution Resolution 5M 3M 2M 1M VGA / D1 CIF Value of M 37 27 22 14 3 1 -4- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 1.4. Specification Communication & Data Transmission Protocol ASCII and Modbus RTU Interface RS-485 differential 2 half/duplex wires Speed 1.2Kbps to 115.2Kbps auto-switching Data Format Data bit 8; Parity Check: None; Stop Bit: 1 Distance Maximum 4000 ft (1200m) Digital Output Isolation 3750Vrms Electrical Characteristics Power Input Voltage DC +10V to +30V Maximum Output Voltage +30V Maximum Output Current 100mA Power Supply Screw terminal, or external DC adapter. Power Consumption 1.5W Physical Characteristics Connection Type Screw terminal for maximum AWG# 12~30 wire Status LED Status LED for power and all output channels Dimension 151mm x 75mm x 26mm Weight 395g -5- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System Environment Characteristics Operating Temperature 0 to 65 degrees C Storage Temperature -20 to 65 degrees C Humidity 10~90%, non-condensing -6- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 2. Overview To apply C24 to your surveillance system, get to know it first. Take a look around C24. The illustration below depicts C24 by top view and side view, with all major components and dimensions called out. Side View Top View Fig. 1. Overview -7- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 2.1. Pin Definition Name Description EXT PWR External power for isolation. Max. 30V DC. EXT. GND External ground for isolation. Max. 30V DC. DIA Digital output Channel 10 DIB Digital output Channel 11 DIC Digital output Channel 12 DID Digital output Channel 13 DIE Digital output Channel 14 DIF Digital output Channel 15 DATA+ RS485+ DATA- RS485- DC 10-30V Input DC 10~30V GND DC Ground DI0 Digital output channel 0 DI1 Digital output channel 1 DI2 Digital output channel 2 DI3 Digital output channel 3 DI4 Digital output channel 4 DI5 Digital output channel 5 DI6 Digital output channel 6 DI7 Digital output channel 7 DI8 Digital output channel 8 DI9 Digital output channel 9 -8- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 3. Configure Protocol & Self-test C24 supports two protocols, Modbus RTU and ASCII, to communicate with the monitoring peripherals. Which protocol to use is adjustable by the 2-toggle dip-switch on one side of C24 as depicted in Overview. The external dip-switch also enters C24 into self-test whereby C24 examines itself to make sure its hardware is working properly Fig. 2. Dip-Switch -9- The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 3.1. Communication Defaults In default state, C24 communicates by the following profile: Item Description Protocol Modbus RTU ID address 01 Baud rate 9600 DIO mode type 40 Checksum Disabled RS485 data format Data bit 8; Parity Check: None Stop Bit: 1 - 10 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 3.2. Back to Initial The dip-switch supports “Back to Initial”, a function that puts a set of communication settings back to “initial” state in case they cannot be remembered and thus disable C24 from being communicated with. The “initial” state represents: Setting Value ID 00 BD 9600 DF 00 Name: TRPC24 To bring C24 “Back to Initial”: Step 1: Close Mainconsole if it is opened. Step 2: Connect C24 to power if you haven’t. Step 3: Adjust dip-switch toggles to “off-off” position. Step 4: Disconnect C24 from power. Step 5: Adjust the toggles to “on-off” position. Step 6: Reconnect C24 to power. Step 7: Adjust the toggles to “off-on” position and C24 goes back to initial. - 11 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 4. Network Deployment Diagram This diagram shows how server, converter (C08), I/O box (C24) are deployed within the surveillance network to work. C08 is subject to connection to maximum 256 I/O boxes (C24/C26/C28), with each I/O box identified by an address ranging from 0~255. Fig. 3. Network Deployment Diagram - 12 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 5. Hardware Setup This chapter combs through the necessary setup for the major components in the surveillance network including: 1. 2. 3. 4. peripherals, I/O box C24, converter C08, Windows-based server PC. 5.1. Connect C08 to Server PC An average Windows-based PC isn’t capable of RS485 communication. Therefore it needs C08, a USB-to-RS485 converter, to be able to talk to C24. Step 1: Connect C08 to PC an USB cable. Step 2: On PC, install C08 driver. - C08 driver is downloadable at www.nuuo.com > Download Once driver is successfully installed, PC auto-detects C08 and generates a COM port for C08. Check it up by clicking Start > Settings > Control Panel > System > Hardware tabbed page > Device Manager. Click the plus (+) of Ports (COM & LPT). The COM port(s) in use will show. - 13 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System 5.2. Connect C24 to C08 After C08 and server are connected and a COM port is up between them, proceed to connect C24 to C08. Connect C08 (TX+, DATA+) to C24 (DATA+). Connect C08 (TX-, DATA-) to C24 (DATA-). 5.3. Connect C24 to Power Supply Connect C24 to power supply by the power adopter that comes with your purchase. 5.4. Connect Peripherals to C24 & Power Supply Step 1: Split a power supply to negative pole and positive pole. Step 2: Connect the positive pole to C24’s EXT.PWR port. Step 3: Connect the negative pole to C24’s EXT.COM port. Step 4: Connect the negative pole of each peripheral to C24’s DO (digital output) ports. Step 5: Bridge the positive poles of the peripheral devices to C24’s EXT.PWR port. Fig. 4. Connect Peripherals to C24 & Power Supply By the example of Fig. 4, each digital input and output device requires at least 4.0V. - Input logical level 0: +1V (max). - Input logical level 1: +4.0V ~ +30V. 5.5. Check C24 COM port, Baud Rate & Address Step 1: Run Oconfig.exe on PC. Step 2: IOconfig.exe is downloadable at www.nuuo.com > download Step 3: Note to close Mainconsole before running IOconfig.exe - 14 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System Step 4: IOConfig opens. Step 5: On the left pane of IOConfig, click Scan button. Step 6: IOConfig proceeds to check the COM port, baud rate and address for the connected C24. Step 7: In a few seconds the checking is through. Scan result shows on the right pane. 5.6. Configure Mainconsole Step 1: Open Mainconsole on PC. Step 2: From Mainconsole tool bar, click button. Step 3: A menu opens. Step 4: Click Setting > System Setting. Step 5: Setting page opens featuring a series of tabs. Step 6: Click I/O Device tab. I/O Device tabbed page opens. Step 7: In Module field, dub C24 with a name. Step 8: By Device, specify C24 model name. Step 9: By COM Port, select the COM port of C24 as you have noted in section 5.5. Check C24 COM port, - 15 - The Intelligent Surveillance Solution NUUO NVR/DVR/Hybrid NDVR System Baud Rate & Address. Step 10: By ID, select the ID address for C24. Step 11: Run Digital Output Simulation. If the graphic in question lights on red, the setup is successfully made. Step 12: Click lower-right OK and quit setting. - 16 -